スポンジクリーニングボールのトラブルシューティング:ボールの詰まり、洗浄不良、早期摩耗

A symptom-first troubleshooting guide for sponge cleaning balls: identify causes of sticking, poor wiping, wear, and ATCS carryover—and apply fixes in the right order.
Troubleshooting Sponge Cleaning Balls

目次

イントロ

Even with the correct ball size and material, sponge cleaning balls can sometimes stick, slow down, clean poorly, or wear out too quickly—especially in pipelines with reducers, bends, aged surfaces, or inconsistent geometry.
This troubleshooting guide gives you quick, practical fixes for the most common problems: stuck balls, weak wiping, uneven ball exit speeds, premature wear, and sizing/hardness mistakes.

Why Troubleshooting Matters

Solving cleaning-ball issues isn’t just about getting a ball through the line—it’s about protecting your equipment, productivity, and safety. When a sponge ball doesn’t behave as expected, it can signal deeper problems in the system:

  • Incorrect ball size or hardness
  • Hidden restrictions such as lips, scale, or worn reducers
  • Flow/pressure misalignment
  • Old hoses or ovalized sections
  • Tube/pipe conditions changing over time

A stuck or underperforming ball can lead to:

  • Longer cleaning time
  • Higher pump pressure
  • Poor wiping that leaves residue behind
  • Excessive ball wear or tearing
  • Risk of pipeline blockage if ignored

This troubleshooting guide helps you quickly identify what went wrong, whyそして how to fix it fast, with clear links to sizing, materials, and best practices:

Problem 1 — Ball Gets Stuck or Slows Down

A sponge cleaning ball getting stuck, slowing dramaticallyあるいは pausing at certain points is the most common and most disruptive issue. Fortunately, the root causes are predictable—and so are the fixes.

Common Causes

  • Ball is too hard → cannot compress enough to pass tight geometry
  • Oversize too aggressive → excessive friction at reducers/elbows
  • Internal lip or weld bead inside a reducer or fitting
  • 楕円形ホース reducing effective I.D.
  • Flow too fast → ball wedges instead of compressing gradually
  • Ball saturated/aged → rebound weakened, reducing passability

Quick Fix Sequence (Use in This Order)

1. Switch to a Softer Hardness (Most Effective Fix)

Softening hardness often solves the issue without reducing ball size, ensuring wiping performance is maintained.
Hard → Medium → Soft

Reference hardness behaviors:
https://www.kinsoe.com/sponge-ball-materials-hardness/

2. Reduce Ball Diameter Slightly

If the ball still sticks, step down the diameter without dropping below oversize.
例えば、こうだ:

  • 80 mm oversize → try 75 mm
  • 75 mm → try 70 mm

Do NOT match nominal pipe size—always size to actual I.D.:
https://www.kinsoe.com/sponge-ball-sizing-guide/

3. Inspect Reducers & Couplings

Most stuck-ball problems originate here. Look for:

  • Internal lips
  • Sharp transitions
  • Misaligned clamps
  • Worn rubber gaskets
  • Dried slurry buildup

A quick internal cleaning, grinding, or gasket replacement often eliminates the recurring issue.

4. Adjust Flow Speed

Too-fast flow can jam a ball into elbows or reducers.
Try:

  • Slower startup
  • More gradual flow increase
  • Maintaining steady, non-surging pressure

This is especially important for コンクリートホース そして boom sections.

5. For ATCS Systems: Verify Tube Geometry

ATCS rarely jams unless:

  • Tube support plates are misaligned
  • There is unexpected tube denting
  • Balls have shrunk (losing wiping compression)

If ATCS balls pause or move inconsistently, replace aged balls:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

When to Escalate to Two-Ball or Special Methods

If the line has:

  • Complex geometry
  • Long booms
  • 急勾配の垂直セクション
  • Heavy residue

Switch to the ツーボール法 for more uniform wiping and better movement.

Two-ball guide (Concrete Cleaning):
https://www.kinsoe.com/concrete-pump-line-cleaning/

Problem 2 — Poor Cleaning / Slurry or Biofilm Still Present

When the ball exits cleanly but slurry, fines, or biofilm remain inside the pipe or tube, the issue is almost always related to wipe pressure, contact areaあるいは ball characteristics. Fortunately, these issues are easy to correct.

Common Causes

  • Ball too small → insufficient wall contact
  • Hardness too soft → conforms well but doesn’t scrub aggressively
  • Ball material not suitable (rubber vs. PU)
  • Incorrect surface finish for fouling type
  • Tube/pipe conditions changed (scale, roughness, temperature)
  • Flow skipping → ball glides too fast to wipe properly

Fast Fixes

1. Increase Oversize Within Safe Limits

A ball that’s too small cannot generate enough wiping pressure.

Typical increases:
+5% → +10% → +20% (depending on hardness and geometry)

Do not oversize beyond what your reducers can handle.

サイズ規定:
https://www.kinsoe.com/sponge-ball-sizing-guide/

2. Step Up Hardness (Soft → Medium → Hard)

If oversize is correct but cleaning is weak:

  • Move from ソフト → ミディアム for stronger wipe
  • 用途 ハード only if tube/pipe geometry is confirmed (especially in ATCS)

Hardness reference:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Consider PU for Abrasive or Older Lines

PU balls:

  • Hold shape longer
  • Deliver stronger wiping force
  • Are better for slightly abrasive pipelines

Rubber balls:

  • Conform better
  • Are ideal for tight bends and mixed hose–steel systems

4. Choose the Right Surface Finish

Match to fouling type:

  • スムーズ → light biofilm
  • 細かい畝 → slime or early soft scale
  • 研磨リング → light mineral scale (use sparingly)

More details:
https://www.kinsoe.com/atcs-ball-selection-dosing/

5. Correct Flow Speed

If the ball moves too quickly, it doesn’t have time to wipe.

Signs of skipping:

  • Inconsistent cleaning
  • Clean sections alternating with dirty ones
  • Ball exits faster than expected

修正:

  • Reduce flow rate
  • Start slower, increase gradually
  • Switch to softer hardness for better compression

Concrete Pipeline Specific Note

If poor cleaning occurs in concrete lines:

  • Try ツーボール法 for heavy slurry
  • Inspect reducers for buildup
  • Consider PU for abrasive sand/cement mixtures

具体的な方法の参照:
https://www.kinsoe.com/concrete-pump-line-cleaning/

ATCS Specific Note

For chiller/condenser systems:

  • If biofilm remains, increase 投与回数
  • Adjust ball surface texture
  • Check for ball shrinkage (common cause of weak wiping)

温度と再利用:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

Problem 3 — Premature Wear, Tearing, or Flattening

When sponge cleaning balls wear out faster than expected, it’s usually a sign that either the pipeline/tube conditions are harsher than normal or the ball material/hardness is mismatched to the application. Premature wear includes tearing, flattening, surface abrasion, or rapid shrinkage.

Common Causes

  • Rough or aged pipe interior (rust, scale, weld beads, scoring)
  • Incorrect material for abrasive conditions
  • Hardness too soft, causing deformation under load
  • Excessively high pump speeds
  • Ball size too large, creating unnecessary friction
  • Chemical exposure or high temperature degrading sponge elasticity

Fast Fixes

1. Switch to PU for High Abrasion or Old Pipework

PU sponge balls have superior:

  • 耐摩耗性
  • Shape retention
  • Longevity in rough conditions

Ideal for:

2. Increase Hardness (Soft → Medium)

If the ball is deforming or flattening:

  • Move to Medium hardness
  • 避ける ハード unless geometry is smooth and verified

Medium hardness greatly reduces tearing in pipelines with:

  • Weld beads
  • Internal lips
  • 減速機
  • Rough bends

3. Reduce Oversize (But Stay Above I.D.)

Oversizing too aggressively increases friction → rapid wear.

Try stepping down diameter:

4. Adjust Pump Flow Speed

High, surging, or unstable flow creates:

  • Excessive rotational friction
  • Sudden pressure spikes at elbows
  • Increased scraping wear

修正する: maintain steady, moderate flow.

5. Inspect Pipeline for Mechanical Damage

Frequent tearing often signals:

  • Sharp weld beads
  • Protruding reducer lips
  • Misaligned gaskets
  • Hose ovalization
  • Scale or corrosion buildup

These create abrasive contact points.
Fixing one sharp reducer can double ball lifespan.

6. Temperature & Chemical Effects

Heat and water chemistry affect sponge elasticity.

Signs:

  • 収縮
  • スロー・リバウンド
  • Hard, glazed surfaces

Reference lifespan & temperature guide:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

ATCS-Specific Note

ATCS balls wear prematurely when:

  • Tube sheet edges are sharp
  • Strainers are misaligned
  • Ball cycles/hour are too high
  • Ball shrinkage goes unnoticed

Ensure weekly QC checks of:

  • ΔT
  • ΔP
  • Ball capture efficiency

Concrete Pipeline Note

Premature wear in concrete lines usually signals:

  • Abrasive sand content
  • Rough elbows
  • Hard balls scraping reducers
  • Oversize too large

Use:

  • PUミディアム for abrasive slurries
  • Rubber Soft for complex bends

Problem 4 — Uneven Movement, Ball Speed Variations, or “Skipping”

Uneven movement—where the ball suddenly speeds up, slows down, or “skips” sections of the line—is a classic sign that the ball is not maintaining consistent wall contact. This leads to patchy cleaning, unpredictable pressure patterns, and poor overall performance.

Common Causes

  • Ball too small → cannot maintain wiping pressure
  • 硬度が高すぎる → insufficient compression
  • Flow rate too high → ball glides instead of wiping
  • Mixed hose + steel transitions causing friction changes
  • 楕円形ホース reducing contact area
  • Ball surface too smooth for the fouling type
  • Ball shrinkage from temperature or age

Quick Fixes

1. Increase Oversize Slightly (Most Common Fix)

Skipping almost always means the ball is not wide enough to keep pressure on the pipe/tube walls.

Typical adjustments:

  • +5%
  • +10% (if tube geometry allows)

Always size to actual I.D., not nominal:
https://www.kinsoe.com/sponge-ball-sizing-guide/

2. Step Down Hardness

If oversize is correct but the ball still skips:

  • Hard → Medium
  • Medium → Soft

Softening improves compression and continuous contact.

Hardness guide:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Adjust Flow Rate

Skipping often happens when flow is too fast, causing the ball to glide over deposited films.

修正:

  • Reduce initial flow
  • Increase gradually
  • Maintain steady, non-surging pressure

This is critical for:

  • Concrete pump hoses
  • Long flexible sections
  • ATCS tubes with varying velocities

4. Use a Surface Type That Matches Fouling

If the ball is too smooth for the debris type:

  • に切り替える。 fine ridged for slime
  • に切り替える。 abrasive ring for early soft scale (ATCS only)
  • Avoid coarse open-cell for ATCS—they deform too much

Surface selection:
https://www.kinsoe.com/atcs-ball-selection-dosing/

5. Check for Ball Shrinkage (ATCS Issue)

In ATCS systems, skipping is often caused by ball shrinkage due to heat or age.

If the ball rebounds slowly or looks undersized:

  • Replace immediately
  • Check temperature exposure

Temperature & lifespan guide:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

Pipeline-Specific Notes

Concrete Lines

Skipping usually occurs:

  • After reducers
  • At hose–steel transitions
  • Inside long hoses that have stretched or ovalized

修正する:

  • Increase oversize わずかに
  • に切り替える。 Rubber Soft for better conformity

ATCS Systems

Skipping indicates:

  • Incorrect ball diameter
  • Wrong hardness (too hard)
  • Insufficient dosing frequency
  • Tube sheet or support misalignment

修正する:

  • Step down hardness
  • Increase dosing cycles
  • Replace shrunken balls

Problem 5 — Balls Not Returning / Carryover in ATCS

In Automatic Tube Cleaning Systems (ATCS), every sponge ball must complete the circuit:
inject → wipe → capture → recirculate.
If balls fail to return or escape downstream (“carryover”), ATCS performance drops immediately — wiping frequency drops, fouling increases, and the system may lose cleaning control altogether.

This issue is rare when the system is properly sized and maintained, but when it happens, it’s always important to correct quickly.

Common Causes

  • Incorrect ball diameter (usually too small) → passes through strainers
  • Ball hardness too high → reduces compression, enabling bypass
  • Ball shrinkage from temperature, age, or chemical exposure
  • Strainer gaps too wide or worn screens
  • 流速が速すぎる → pushes balls past capture screens
  • Damaged recirculation piping or misaligned return valves
  • Foreign debris blocking or deforming the strainer mesh
  • Excess dosing frequency → system overloaded with too many balls

Fast Fixes

1. Increase Ball Diameter (Most Common Fix)

If balls are slipping through strainers, they are 小さすぎる for the tube I.D.
Increase diameter by +1–2 mm increments until 100% capture is achieved.

サイズ規定:
https://www.kinsoe.com/sponge-ball-sizing-guide/

2. Switch to Softer or Medium Hardness

Hard balls compress 少ない, which can allow them to bypass strainer slots.

Recommended:

  • Soft → Best passability + reliable capture
  • Medium → More wiping strength + still compressible

Hardness comparison:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Replace Shrunken or Aged Balls

ATCS sponge balls naturally shrink over time due to:

  • Heat
  • 化学物質への暴露
  • High-cycle compression
  • Mechanical wear

Shrunken balls lose compression and escape strainers.

Check ball diameter weekly.
If shrinkage > 5–8%, replace immediately.

Lifespan guide:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

4. Inspect Strainer Screens

Carryover can happen if:

  • Mesh is damaged
  • Gaps enlarged from wear
  • Screens installed incorrectly
  • Strainer basket not fully seated

Fixes include restoring mesh integrity, cleaning accumulated debris, and aligning the capture basket.

5. Reduce Flow Velocity Slightly

If condenser water velocity is too high:

  • Balls may strike the strainer forcefully
  • Compression may not occur
  • Some may bypass the capture screen

Lower flow just enough to stabilize capture efficiency.

6. Check Recirculation Valves & Piping

Misaligned valves or partially closed return lines can divert balls:

  • To drains
  • To bypass lines
  • Into downstream components

Ensure:

  • Clear return path
  • Proper valve alignment
  • No air pockets obstructing recirculation

7. Review Dosing Frequency

Overdosing causes:

  • Ball collisions
  • Incomplete capture
  • Balls stacking in strainers
  • Increased escape risk

Start with:

  • 1~4サイクル/時
  • チューブ1本につきボール1個 (varies by chiller model)

Dosing details:
https://www.kinsoe.com/atcs-ball-selection-dosing/

Signs You Fixed the Problem

  • 100% ball recovery
  • Stable cleaning performance
  • No unexplained ΔT increases
  • No strainers overflowing with balls
  • Ball condition remains consistent

Problem 6 — Foam or Water Discoloration (Quality Issues)

When the water exiting the pipeline or ATCS loop appears foamy, colored, cloudy, or contaminated, the issue may not lie with the sponge ball itself, but with the pipeline condition, residue type, or chemical interaction. This section helps identify what each discoloration type means — and how to fix it.

Common Causes

  • Residue buildup inside the pipe/tube releasing during wiping
  • Ball material breakdown from high temperature or chemical exposure
  • Incorrect ball type for the operating medium
  • Biofilm release in ATCS systems
  • Slurry contamination after concrete discharge
  • Old rubber particles detaching from worn sponge balls
  • Chemical reactions between ball material and additives in the water

What the Water Color/Condition Tells You

1. Brown / Rusty Water

Likely cause:

  • Rust or corrosion flakes in steel pipe interiors
  • Old weld beads shedding material
  • Tube corrosion in ATCS condensers

修正:

  • Inspect steel sections for corrosion
  • に切り替える。 PUミディアム for better durability
  • Increase initial flushing volume

2. Grey / Cement-Colored Water (Concrete Lines)

Likely cause:

  • Residual slurry clinging to the hose/pipe
  • Ball too small or too soft
  • Poor wipe pressure

修正:

3. White Foam

Likely cause:

  • High turbulence in concrete or ATCS systems
  • Chemical additives reacting with sponge material
  • Ball material fatigue (older rubber balls)

修正:

  • Reduce flow rate
  • Check chemical compatibility
  • Replace worn balls

4. Black Rubber Dust or Particles

Likely cause:

  • Ball abrasion on rough surfaces
  • Rubber balls wearing rapidly
  • Aggressive abrasive conditions inside pipe

修正:

  • に切り替える。 PUミディアム
  • Inspect for sharp edges or weld beads
  • Reduce oversize or hardness

5. Green, Yellow, or Biofilm-Colored Discharge (ATCS)

Likely cause:

  • ATCS successfully wiping out biofilm
  • Early-stage slime or algae being removed

修正:

General Fixes for Water-Quality Issues

1. Inspect the Ball Condition

If the ball shows:

  • グレージング
  • クラッキング
  • スロー・リバウンド
  • Surface shedding

→ すぐに交換する
Temperature & Reuse Guide:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

2. Inspect the Pipeline Interior

Check for:

  • Rough welds
  • Corrosion
  • Scale
  • Debris pockets
  • Reducer damage

These can all cause discoloration during cleaning.

3. Match Ball Material to the Operating Medium

  • Rubber = best passability
  • PU = best abrasion resistance
  • Closed-cell = best for clean water (ATCS)
  • Open-cell = best for uneven concrete hoses

Material guide:
https://www.kinsoe.com/sponge-ball-materials-hardness/

4. Adjust Flow Speed

Excess turbulence or aggressive flow can create foaming and dislodge too much residue at once.

Aim for steady, moderate flow.

Problem 7 — Too Many Balls Required / Low Cleaning Efficiency

If your crew or operators find themselves using more sponge balls than usual or need multiple cleaning passes to get acceptable results, this indicates a mismatch between ball characteristics, pipeline/tube conditionsあるいは 投与戦略.
This usually means efficiency is low — but fortunately, the fixes are straightforward.

Common Causes

  • Ball too small → insufficient wiping pressure
  • Hardness too soft → good passability, but weak scrubbing
  • Wrong surface type → smooth balls on slime or soft scale
  • Ball shrinkage over time (ATCS issue)
  • Pipeline fouling too heavy for a single pass
  • Oversize too conservative → wipe too gentle
  • Flow rate too high → skipping/under-wiping
  • Old or rough pipelines tearing balls prematurely
  • Incorrect dosing frequency in ATCS systems

Fast Fixes

1. Increase Oversize (Most Common Efficiency Fix)

When cleaning efficiency is low, the first adjustment is almost always オーバーサイズ.

Typical oversize adjustments:

  • +5% for Soft
  • +10% for Medium
  • +5–8% for ATCS systems (tight tolerances)

Correct sizing reference:
https://www.kinsoe.com/sponge-ball-sizing-guide/

2. Increase Hardness (Soft → Medium)

If the oversize is correct but the ball still cleans weakly:

  • Switch from Soft → Medium hardness
  • In ATCS, Medium is often used for mild slime or soft scale
  • Use Hard only if geometry is verified smooth

Hardness interaction guide:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Switch to PU for Stronger, Longer Wiping

PU balls scrub more aggressively and keep their shape longer, especially when:

  • Tubes are slightly rough
  • Concrete hoses have abrasive fines
  • Long pipelines cause rubber balls to deform

Rubber = best for tight bends
PU = best for strong, consistent wiping

4. Match Surface Type to Fouling

  • Smooth: thin biofilm
  • Fine ridged: slime and early soft scale
  • Abrasive ring: stubborn scale (temporary use only)

Surface selection & dosing:
https://www.kinsoe.com/atcs-ball-selection-dosing/

5. Check Flow Rate

Flow that’s too high causes:

  • Skipping
  • Weak wiping
  • Irregular ball contact

修正する:

  • Reduce initial flow
  • Ramp up gradually
  • Maintain steady pressure

6. Address Pipeline Fouling Level

If the line hasn’t been cleaned in a long time:

  • Heavy slime → use ridged balls
  • Light scale → short-term abrasive-ring balls
  • Concrete residue → two-ball method or increase oversize

Concrete methods:
https://www.kinsoe.com/concrete-pump-line-cleaning/

7. ATCS-Specific Fixes

Low cleaning efficiency in ATCS often means:

  • Dosing too infrequent
  • Ball shrinkage has reduced wiping pressure
  • Wrong hardness or surface finish
  • Strainers not capturing all balls → incomplete cycles

Reset by:

  • Increasing cycles/hour
  • Replacing shrunken balls
  • Using fine-ridged surfaces
  • Adjusting hardness/oversize

Temperature & Reuse Guide:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

If You Need Too Many Balls Too Often…

This indicates a deeper issue:

  • Rough pipeline
  • Corroded reducers
  • Tight bends
  • 楕円形ホース
  • Unsupported ATCS tubes

Inspect pipeline conditions and note any recurring slowdown points.

Problem 8 — Balls Wearing Out Too Slowly or Not Cleaning Aggressively (Underperformance)

It may sound counterintuitive, but sometimes sponge cleaning balls last too long—a sign that they are not applying enough wiping pressure.
If a ball shows almost no wear after many passes, it usually means insufficient compression, wrong surface typeあるいは too-soft hardness, resulting in under-cleaning.

This is especially important for:

  • Concrete pipelines with heavy fines
  • Condenser/chiller tubes with persistent slime
  • ATCS systems with stable but 徐々に declining performance
  • Older steel pipes with rough interiors

Common Causes

  • Ball oversized too little
  • Hardness too soft for the fouling type
  • Smooth surface used on sticky slime/soft scale
  • Tube/pipe geometry too smooth for the chosen ball (ATCS)
  • Flow velocity too low (ball not fully engaging walls)
  • Ball too small due to shrinkage (ATCS shrinkage is common)

Fast Fixes

1. Increase Oversize

Insufficient wiping pressure = too small ball or too tight tolerance.

Typical increases:

  • Soft balls: +10–20%
  • Medium balls: +10–15%
  • ATCS balls: +1–2 mm only (tight limits)

Sizing guide:
https://www.kinsoe.com/sponge-ball-sizing-guide/

2. Step Up Hardness

If oversize feels correct but wiping is weak:

  • ソフト → ミディアム
  • Medium → Hard (only if geometry is confirmed smooth)

Medium is the most common solution for general wiping improvements.

硬度の指導:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Select a More Aggressive Surface

Switch from smooth → ridged → abrasive (where safe):

  • Smooth: basic biofilm
  • Fine ridged: slime, algae, soft scale
  • Abrasive ring: stubborn scale or deposits (ATCS short-term use only)

ATCS surface selection & dosing:
https://www.kinsoe.com/atcs-ball-selection-dosing/

4. Increase Flow Slightly

If flow is too low:

  • Ball glides instead of wiping
  • Compression is weak
  • Dead zones remain uncleaned

Increase flow gradually until the ball shows:

  • Consistent movement
  • Balanced pressure
  • Slight rotational motion

5. Replace Old or Shrunken Balls

In ATCS systems, shrinkage reduces:

  • 圧縮
  • Wipe pressure
  • Surface contact

Ball shrinkage > 5–8% = replace.
Temperature & Reuse guidance:
https://www.kinsoe.com/sponge-ball-temperature-reuse/

Concrete and Pipeline Considerations

Weak wiping often indicates:

  • Wrong surface type
  • Too-soft hardness
  • Old hoses giving too much internal friction variation

Fix with:

  • Medium hardness
  • Larger oversize
  • Proper surface type

Concrete cleaning steps:
https://www.kinsoe.com/concrete-pump-line-cleaning/

ATCS Considerations

Underperformance signs:

  • ΔT slowly rising
  • Fouling returning between cycles
  • Balls exiting too clean (no residue)
  • Dosing too infrequent

修正する:

  • Increase dosing cycles/hour
  • Replace worn balls
  • Switch surface type
  • Increase diameter slightly

Problem 9 — Mis-sizing, Wrong Hardness, or Wrong Cell Structure

A large percentage of cleaning issues—whether in コンクリートライン または ATCS condenser tubes—ultimately trace back to incorrect ball size, hardness, or cell structure. Even small errors can make the difference between perfect wiping and complete failure.
This section shows how to identify mis-sizing problems quickly and how to correct them with the right specifications.

Common Symptoms of Mis-Sizing or Wrong Hardness

  • Ball moves too fast → too small or too hard
  • Ball gets stuck at reducers → too large or too hard
  • Patchy cleaning → size too small or hardness too high
  • 過度の摩耗 → oversize too aggressive or pipe interior rough
  • Ball doesn’t compress → too hard or wrong material
  • Poor passability in bends → hardness too high, oversize too high
  • ATCS balls not captured → diameter too small or shrunken

How to Diagnose Sizing Problems

1. Match Ball Diameter to Actual I.D., Not Nominal

A common mistake is sizing to pipe/hose “nominal” dimensions.
Always measure the 実内径, especially at:

  • 減速機
  • Hose sections (which may ovalize)

Correct sizing reference:
https://www.kinsoe.com/sponge-ball-sizing-guide/

Diagnosis clues:

  • If the ball exits with little resistance → too small
  • If pressure spikes at reducers → too large or too hard

2. Check Hardness Against Geometry

Hardness determines compression and passability.

ソフト

  • Best for tight bends, mixed hose + steel, reducers
  • Ideal for ATCS passability

ミディアム

  • Balanced wiping & movement
  • Common for concrete and ATCS slime control

ハード

  • Use only on smooth geometry そして moderate oversize
  • High risk of sticking if mis-sized

Hardness behavior guide:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Confirm Cell Structure

Choosing open-cell vs closed-cell has consequences:

オープンセル

  • High compression
  • Excellent pipe conformity
  • Best for concrete lines and old hoses

クローズド・セル

  • Predictable shape retention
  • 吸水率が低い
  • Best for ATCS and smooth tubes

If the ball feels “spongy” or collapses too easily, cell structure may be wrong for the medium.

4. Verify Material Choice

ゴム

  • Best passability
  • よりソフトな圧縮
  • Great for long/complex pipelines

PU

  • Better abrasion resistance
  • Holds shape longer
  • Best for rough steel lines or high-cycle ATCS

Switching materials is one of the fastest fixes for chronic mis-sizing issues.

Fast Fixes by Symptom

Ball moves too easily / poor cleaning

  • Increase oversize
  • Move to Medium hardness
  • Switch to ridged or abrasive surface in ATCS
  • Check for shrinkage (ATCS issue)

Ball gets stuck at reducers

  • 硬さを和らげる
  • Reduce oversize slightly
  • Inspect reducer for lips or misalignment

Ball wears too fast

  • Reduce oversize
  • Switch to PU
  • Check pipe interior for sharp edges
  • Reduce pump speed during bends

Ball “skips” or speeds up

  • Increase oversize
  • Step down hardness
  • Reduce flow rate
  • Switch surface type

Special Note for ATCS Systems

ATCS mis-sizing almost always comes from:

  • Ball shrinkage
  • 硬度が高すぎる
  • Diameter too small for strainer capture
  • Wrong surface type for fouling type

Dosing & surface guidance:
https://www.kinsoe.com/atcs-ball-selection-dosing/

Special Note for Concrete Pipelines

Mis-sizing is common due to:

  • Hose stretch/ovalization
  • Reducers with hidden lips
  • Abrasive fines that wear balls quickly

Sizing + hardness must balance wipe そして 通過性.

Concrete cleaning steps:
https://www.kinsoe.com/concrete-pump-line-cleaning/

Conclusion Summary (Skimmable)

If a sponge cleaning ball isn’t performing the way you expect—whether it’s sticking, skipping, cleaning poorly, wearing too fast, or not returning in ATCS—the cause almost always comes down to five controllable factors:

1. Size (Oversize Rules)

The ball must always exceed the 実際のI.D., not nominal size.
Too small → weak cleaning
Too large → sticking at reducers
サイズ規定:
https://www.kinsoe.com/sponge-ball-sizing-guide/

2. Hardness (Soft / Medium / Hard)

Soft → best passability
Medium → balanced wiping
Hard → only for smooth, verified geometry
Hardness guide:
https://www.kinsoe.com/sponge-ball-materials-hardness/

3. Material (Rubber vs PU)

Rubber → flexible, best for bends
PU → durable, best for abrasive or rough lines

4. Cell Structure (Open vs Closed)

Open-cell → concrete lines, uneven hoses
Closed-cell → ATCS, consistent tube geometry

5. Flow Conditions & Geometry

Flow too fast = skipping
Reducers = highest risk for sticking
Ovalized hoses = inconsistent wipe
Elbows = need soft hardness + stable pressure

A well-performing sponge ball will:
✔ Move with stable speed
✔ Maintain wiping pressure
✔ Show moderate, not excessive, wear
✔ Exit the line without hesitation
✔ Improve flow/ΔT/efficiency immediately

If not, use this guide to quickly adjust size, hardness, material, or flow settings.

For full cross-topic understanding, start with the main pillar:
https://www.kinsoe.com/sponge-cleaning-balls-fast-buyers-guide/

If you’re facing stuck balls, weak wiping, unpredictable movement, premature wear, or ATCS recovery problems, we can help you identify the exact size, hardness, material, and surface type your system needs.

Share these details for a precise troubleshooting recommendation:

  • Actual pipe/tube I.D. (measure at reducers, elbows, and hose–steel transitions)
  • システムタイプ: Concrete pipeline / ATCS / other industrial pipe
  • Observed issue: Sticking, skipping, weak cleaning, poor return, rapid wear, etc.
  • 使用媒体と温度
  • Line geometry: Bends, reducers, long hoses, or straight tubes
  • Residue/fouling type: Slurry, slime, biofilm, early scale

We’ll diagnose the cause and suggest ball size + hardness + material + surface combinations that solve it.

高品質のスポンジクリーニングボールが必要ですか?

コンデンサー・システム

製品ページをご覧ください:
👉 スポンジクリーニングボール(Kinsoeゴム)
https://www.kinsoe.com/product/rubber-sponge-cleaning-balls/

全容を見る

👉 スポンジクリーニングボールバイヤーの概要
https://www.kinsoe.com/sponge-cleaning-balls-fast-buyers-guide/

関連テクニカルガイド

サービス

カスタムゴムチューブ

素材ゴム
サイズカスタマイズされるID及びOD
硬度30-80A カスタマイズ
色:カスタマイズ

カスタムラバーシール

材質シリコーン/EPDM
硬度40-80ショアA
サイズカスタマイズ
色:カスタマイズ

カスタムスポンジパーツ

素材シリコーンゴム
サイズ/形状/硬さ:カスタマイズ
色:カスタマイズ

カスタム成形部品

素材ゴム
サイズ/形状/硬さ:カスタマイズ
色:カスタマイズ

こんなに早く出発するのか?

何をお探しでしたか? のために

専門家の助けを得るために、あなたの疑問を共有してください。